Raw Competition Data (Maximum Resolution)
The PerScan.csv files below are approximately 55 MB each.
Raw Competition Data (Aggregated Hourly)
The HourlyData.csv files below are approximately 76 KB each.
CSV Column Metadata
csv_metadata_id | File Name | Team | Column | Header Title | Units | Data Type | Category | Measure Type | Location | Resolution | Aggregation | First Timestamp | Last Timestamp | Details | Notes |
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
1 | DHO_HourlyData.csv | Dhofar | 1 | TmStamp | Timestamp | Timestamp | Timestamp | 1 hour | 2014-11-18 13:00:00 | ||||||
2 | DHO_HourlyData.csv | Dhofar | 2 | Zone1_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 1 (Attic Floor Living Space) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
3 | DHO_HourlyData.csv | Dhofar | 3 | Zone2_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 2 (North Attic Floor Room) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
4 | DHO_HourlyData.csv | Dhofar | 4 | Zone3_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 3 (Majlis) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
5 | DHO_HourlyData.csv | Dhofar | 5 | Zone4_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 4 (West First Floor Room) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
6 | DHO_HourlyData.csv | Dhofar | 6 | Zone1_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 1 (Attic Floor Living Space) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
7 | DHO_HourlyData.csv | Dhofar | 7 | Zone2_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 2 (North Attic Floor Room) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
8 | DHO_HourlyData.csv | Dhofar | 8 | Zone3_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 3 (Majlis) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
9 | DHO_HourlyData.csv | Dhofar | 9 | Zone4_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 4 (West First Floor Room) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
10 | DHO_HourlyData.csv | Dhofar | 10 | Fridge_degC_Avg | °C | Floating Point | Appliances | Temperature | Refrigerator | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
11 | DHO_HourlyData.csv | Dhofar | 11 | Freezer_degC_Avg | °C | Floating Point | Appliances | Temperature | Freezer | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
12 | DHO_HourlyData.csv | Dhofar | 12 | Grid_kWh | kWh | Floating Point | AC Energy | Grid Mains | 1 hour | Sample | 2014-11-18 13:00:00 | ||||
13 | GUT_HourlyData.csv | GUtech | 1 | TmStamp | Timestamp | Timestamp | Timestamp | 1 hour | 2014-11-18 13:00:00 | ||||||
14 | GUT_HourlyData.csv | GUtech | 2 | Zone1_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 1 (Dining Space) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
15 | GUT_HourlyData.csv | GUtech | 3 | Zone2_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 2 (Living Space) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
16 | GUT_HourlyData.csv | GUtech | 4 | Zone3_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 3 (Middle Bedroom) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
17 | GUT_HourlyData.csv | GUtech | 5 | Zone4_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 4 (East/West Bedroom) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
18 | GUT_HourlyData.csv | GUtech | 6 | Zone1_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 1 (Dining Space) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
19 | GUT_HourlyData.csv | GUtech | 7 | Zone2_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 2 (Living Space) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
20 | GUT_HourlyData.csv | GUtech | 8 | Zone3_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 3 (Middle Bedroom) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
21 | GUT_HourlyData.csv | GUtech | 9 | Zone4_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 4 (East/West Bedroom) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
22 | GUT_HourlyData.csv | GUtech | 10 | Fridge_degC_Avg | °C | Floating Point | Appliances | Temperature | Refrigerator | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
23 | GUT_HourlyData.csv | GUtech | 11 | Freezer_degC_Avg | °C | Floating Point | Appliances | Temperature | Freezer | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
24 | GUT_HourlyData.csv | GUtech | 12 | Grid_kWh | kWh | Floating Point | AC Energy | Grid Mains | 1 hour | Sample | 2014-11-18 13:00:00 | ||||
25 | HCT_HourlyData.csv | HCT | 1 | TmStamp | Timestamp | Timestamp | Timestamp | 1 hour | 2014-11-18 13:00:00 | ||||||
26 | HCT_HourlyData.csv | HCT | 2 | Zone1_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 1 (Living Room) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
27 | HCT_HourlyData.csv | HCT | 3 | Zone2_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 2 (Master Bedroom) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
28 | HCT_HourlyData.csv | HCT | 4 | Zone3_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 3 (West Bedrooms) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
29 | HCT_HourlyData.csv | HCT | 5 | Zone4_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 4 (Majlis) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
30 | HCT_HourlyData.csv | HCT | 6 | Zone1_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 1 (Living Room) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
31 | HCT_HourlyData.csv | HCT | 7 | Zone2_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 2 (Master Bedroom) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
32 | HCT_HourlyData.csv | HCT | 8 | Zone3_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 3 (West Bedrooms) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
33 | HCT_HourlyData.csv | HCT | 9 | Zone4_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 4 (Majlis) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
34 | HCT_HourlyData.csv | HCT | 10 | Fridge_degC_Avg | °C | Floating Point | Appliances | Temperature | Refrigerator | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
35 | HCT_HourlyData.csv | HCT | 11 | Freezer_degC_Avg | °C | Floating Point | Appliances | Temperature | Freezer | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
36 | HCT_HourlyData.csv | HCT | 12 | Grid_kWh | kWh | Floating Point | AC Energy | Grid Mains | 1 hour | Sample | 2014-11-18 13:00:00 | ||||
37 | NIZ_HourlyData.csv | Nizwa | 1 | TmStamp | Timestamp | Timestamp | Timestamp | 1 hour | 2014-11-18 13:00:00 | ||||||
38 | NIZ_HourlyData.csv | Nizwa | 2 | Zone1_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 1 (Majlis) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
39 | NIZ_HourlyData.csv | Nizwa | 3 | Zone2_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 2 (Dining/Ground Floor Sitting Room) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
40 | NIZ_HourlyData.csv | Nizwa | 4 | Zone3_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 3 (Kid's Bedroom) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
41 | NIZ_HourlyData.csv | Nizwa | 5 | Zone4_degC_Avg | °C | Floating Point | Indoor Environment | Temperature | Zone 4 (Master Bedroom) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
42 | NIZ_HourlyData.csv | Nizwa | 6 | Zone1_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 1 (Majlis) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
43 | NIZ_HourlyData.csv | Nizwa | 7 | Zone2_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 2 (Dining/Ground Floor Sitting Room) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
44 | NIZ_HourlyData.csv | Nizwa | 8 | Zone3_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 3 (Kid's Bedroom) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
45 | NIZ_HourlyData.csv | Nizwa | 9 | Zone4_pctRH_Avg | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 4 (Master Bedroom) | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
46 | NIZ_HourlyData.csv | Nizwa | 10 | Fridge_degC_Avg | °C | Floating Point | Appliances | Temperature | Refrigerator | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
47 | NIZ_HourlyData.csv | Nizwa | 11 | Freezer_degC_Avg | °C | Floating Point | Appliances | Temperature | Freezer | 1 hour | Average of 20 second measurements | 2014-11-18 13:00:00 | |||
48 | NIZ_HourlyData.csv | Nizwa | 12 | Grid_kWh | kWh | Floating Point | AC Energy | Grid Mains | 1 hour | Sample | 2014-11-18 13:00:00 | ||||
49 | DHO_PerScan.csv | Dhofar | 1 | TmStamp | Timestamp | Timestamp | Timestamp | 20 seconds | None | 2014-11-18 12:00:20 | |||||
50 | DHO_PerScan.csv | Dhofar | 2 | PowerSupply_V | V | Floating Point | Miscellaneous | DC Voltage | Datalogger power supply | 20 seconds | None | 2014-11-18 12:00:20 | |||
51 | DHO_PerScan.csv | Dhofar | 3 | Datalogger_degC | °C | Floating Point | Miscellaneous | Dry-Bulb Temperature | Datalogger wiring panel | 20 seconds | None | 2014-11-18 12:00:20 | |||
52 | DHO_PerScan.csv | Dhofar | 4 | GlobalHoriz_Wm2 | W/m² | Floating Point | Outdoor Environment | Solar Radiation | Weather station | 20 seconds | None | 2014-11-18 12:00:20 | |||
53 | DHO_PerScan.csv | Dhofar | 5 | WindSpeed_mps | m/s | Floating Point | Outdoor Environment | Air Speed | Weather station wind | 20 seconds | None | 2014-11-18 12:00:20 | |||
54 | DHO_PerScan.csv | Dhofar | 6 | OutsideAir_degC | °C | Floating Point | Outdoor Environment | Dry-Bulb Temperature | Weather station | 20 seconds | None | 2014-11-18 12:00:20 | |||
55 | DHO_PerScan.csv | Dhofar | 7 | OutsideAir_pctRH | %RH | Floating Point | Outdoor Environment | Relative Humdity | Weather station | 20 seconds | None | 2014-11-18 12:00:20 | |||
56 | DHO_PerScan.csv | Dhofar | 8 | OutsideAirShield_degC | °C | Floating Point | Radiation Shields | Dry-Bulb Temperature | Weather station radiation shield | 20 seconds | None | 2014-11-18 12:00:20 | |||
57 | DHO_PerScan.csv | Dhofar | 9 | Zone1_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 1 (Attic Living Space) | 20 seconds | None | 2014-11-18 12:00:20 | |||
58 | DHO_PerScan.csv | Dhofar | 10 | Zone1_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 1 (Attic Living Space) | 20 seconds | None | 2014-11-18 12:00:20 | |||
59 | DHO_PerScan.csv | Dhofar | 11 | Zone2_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 2 (North Attic Floor Room) | 20 seconds | None | 2014-11-18 12:00:20 | |||
60 | DHO_PerScan.csv | Dhofar | 12 | Zone2_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 2 (North Attic Floor Room) | 20 seconds | None | 2014-11-18 12:00:20 | |||
61 | DHO_PerScan.csv | Dhofar | 13 | Zone3_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 3 (Majlis) | 20 seconds | None | 2014-11-18 12:00:20 | |||
62 | DHO_PerScan.csv | Dhofar | 14 | Zone3_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 3 (Majlis) | 20 seconds | None | 2014-11-18 12:00:20 | |||
63 | DHO_PerScan.csv | Dhofar | 15 | Zone4_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 4 (West First Floor Room) | 20 seconds | None | 2014-11-18 12:00:20 | |||
64 | DHO_PerScan.csv | Dhofar | 16 | Zone4_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 4 (West First Floor Room) | 20 seconds | None | 2014-11-18 12:00:20 | |||
65 | DHO_PerScan.csv | Dhofar | 17 | DutyCycle_pct | % | Floating Point | Radiation Shields | Duty Cycle | Weather station radiation shield fan input | 20 seconds | None | 2014-11-18 12:00:20 | |||
66 | DHO_PerScan.csv | Dhofar | 18 | Zone1Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 1 (Attic Living Space) radiation shield fan | 20 seconds | None | 2014-11-18 12:00:20 | |||
67 | DHO_PerScan.csv | Dhofar | 19 | Zone2Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 2 (North Attic Floor Room) radiation shield fan | 20 seconds | None | 2014-11-18 12:00:20 | |||
68 | DHO_PerScan.csv | Dhofar | 20 | Zone3Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 3 (Majlis) radiation shield fan | 20 seconds | None | 2014-11-18 12:00:20 | |||
69 | DHO_PerScan.csv | Dhofar | 21 | Zone4Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 4 (West First Floor Room) radiation shield fan | 20 seconds | None | 2014-11-18 12:00:20 | |||
70 | DHO_PerScan.csv | Dhofar | 22 | OutsideFan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Weather station radiation shield fan | 20 seconds | None | 2014-11-18 12:00:20 | |||
71 | DHO_PerScan.csv | Dhofar | 23 | Shower_degC | °C | Floating Point | Water/HVAC | Dry-Bulb Temperature | Shower outlet | 20 seconds | None | 2014-11-18 12:00:20 | |||
72 | DHO_PerScan.csv | Dhofar | 24 | Shower_L | L | Floating Point | Water/HVAC | Liquid Volume | Shower outlet | 20 seconds | None | 2014-11-18 12:00:20 | |||
73 | DHO_PerScan.csv | Dhofar | 25 | Dishwasher_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Dishwasher | 20 seconds | None | 2014-11-18 12:00:20 | |||
74 | DHO_PerScan.csv | Dhofar | 26 | Fridge_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Refrigerator | 20 seconds | None | 2014-11-18 12:00:20 | |||
75 | DHO_PerScan.csv | Dhofar | 27 | Freezer_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Freezer | 20 seconds | None | 2014-11-18 12:00:20 | |||
76 | DHO_PerScan.csv | Dhofar | 28 | PotTemp_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Cooking task pot | 20 seconds | None | 2014-11-18 12:00:20 | |||
77 | DHO_PerScan.csv | Dhofar | 29 | PotLevel_inch | in. | Floating Point | Appliances | Liquid Level | Cooking task pot | 20 seconds | None | 2014-11-18 12:00:20 | |||
78 | DHO_PerScan.csv | Dhofar | 30 | Consumption_A_W | W | Floating Point | Electrical Service | AC Power | Red (A) phase service | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
79 | DHO_PerScan.csv | Dhofar | 31 | Consumption_B_W | W | Floating Point | Electrical Service | AC Power | Yellow (B) phase service | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
80 | DHO_PerScan.csv | Dhofar | 32 | Consumption_C_W | W | Floating Point | Electrical Service | AC Power | Blue (C) phase service | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
81 | DHO_PerScan.csv | Dhofar | 33 | FridgeFreezer_W | W | Floating Point | Appliances | AC Power | Refrigerator/freezer socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
82 | DHO_PerScan.csv | Dhofar | 34 | ClothesWasher_W | W | Floating Point | Appliances | AC Power | Clothes washer socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
83 | DHO_PerScan.csv | Dhofar | 35 | BoosterPump_Modem_W | W | Floating Point | Water/HVAC; Misc. Plug Loads | AC Power | Booster pump/modem socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
84 | DHO_PerScan.csv | Dhofar | 36 | Dishwasher_W | W | Floating Point | Appliances | AC Power | Dishwasher socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
85 | DHO_PerScan.csv | Dhofar | 37 | SolarWaterHeater_W | W | Floating Point | Water/HVAC | AC Power | Solar water heater heating element branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
86 | DHO_PerScan.csv | Dhofar | 38 | SPARE_WN02C_W | W | Floating Point | Miscellaneous | AC Power | Unused meter channel | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
87 | DHO_PerScan.csv | Dhofar | 39 | Cooktop_W | W | Floating Point | Appliances | AC Power | Cooktop socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
88 | DHO_PerScan.csv | Dhofar | 40 | HomeElectronics_W | W | Floating Point | Misc. Plug Loads | AC Power | Home electronics socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
89 | DHO_PerScan.csv | Dhofar | 41 | SPARE_WN03C_W | W | Floating Point | Miscellaneous | AC Power | Unused meter channel | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
90 | DHO_PerScan.csv | Dhofar | 42 | Lighting_Fans_A_W | W | Floating Point | Lighting; Water/HVAC | AC Power | Red (A) phase lighting/fan branch circuits | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
91 | DHO_PerScan.csv | Dhofar | 43 | Lighting_Fans_B_W | W | Floating Point | Lighting; Water/HVAC | AC Power | Yellow (B) phase lighting/fan branch circuits | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
92 | DHO_PerScan.csv | Dhofar | 44 | Lighting_Fans_C_W | W | Floating Point | Lighting; Water/HVAC | AC Power | Blue (C) phase lighting/fan branch circuits | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
93 | DHO_PerScan.csv | Dhofar | 45 | Production_W | W | Floating Point | Power Generation | AC Power | PV inverter feeder | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
94 | DHO_PerScan.csv | Dhofar | 46 | SPARE_WN05B_W | W | Floating Point | Miscellaneous | AC Power | Unused meter channel | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
95 | DHO_PerScan.csv | Dhofar | 47 | SPARE_WN05C_W | W | Floating Point | Miscellaneous | AC Power | Unused meter channel | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
96 | DHO_PerScan.csv | Dhofar | 48 | Consumption_W | W | Floating Point | Electrical Service | AC Power | Combined service | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
97 | DHO_PerScan.csv | Dhofar | 49 | Lighting_Fans_W | W | Floating Point | Lighting; Water/HVAC | AC Power | Combined lighting/fan branch circuits | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
98 | DHO_PerScan.csv | Dhofar | 50 | Grid_W | W | Floating Point | Electrical Service | AC Power | Net service/PV inverter feeder | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
99 | DHO_PerScan.csv | Dhofar | 51 | Consumption_A_kWh | kWh | Floating Point | Electrical Service | AC Energy | Red (A) phase service | 20 seconds | None | 2014-11-18 12:00:20 | |||
100 | DHO_PerScan.csv | Dhofar | 52 | Consumption_B_kWh | kWh | Floating Point | Electrical Service | AC Energy | Yellow (B) phase service | 20 seconds | None | 2014-11-18 12:00:20 | |||
101 | DHO_PerScan.csv | Dhofar | 53 | Consumption_C_kWh | kWh | Floating Point | Electrical Service | AC Energy | Blue (C) phase service | 20 seconds | None | 2014-11-18 12:00:20 | |||
102 | DHO_PerScan.csv | Dhofar | 54 | FridgeFreezer_kWh | kWh | Floating Point | Appliances | AC Energy | Refrigerator/freezer socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
103 | DHO_PerScan.csv | Dhofar | 55 | ClothesWasher_kWh | kWh | Floating Point | Appliances | AC Energy | Clothes washer socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
104 | DHO_PerScan.csv | Dhofar | 56 | BoosterPump_Modem_kWh | kWh | Floating Point | Water/HVAC; Misc. Plug Loads | AC Energy | Booster pump/modem socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
105 | DHO_PerScan.csv | Dhofar | 57 | Dishwasher_kWh | kWh | Floating Point | Appliances | AC Energy | Dishwasher socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
106 | DHO_PerScan.csv | Dhofar | 58 | SolarWaterHeater_kWh | kWh | Floating Point | Water/HVAC | AC Energy | Solar water heater heating element branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
107 | DHO_PerScan.csv | Dhofar | 59 | SPARE_kWhN02C_kWh | kWh | Floating Point | Miscellaneous | AC Energy | Unused meter channel | 20 seconds | None | 2014-11-18 12:00:20 | |||
108 | DHO_PerScan.csv | Dhofar | 60 | Cooktop_kWh | kWh | Floating Point | Appliances | AC Energy | Cooktop socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
109 | DHO_PerScan.csv | Dhofar | 61 | HomeElectronics_kWh | kWh | Floating Point | Misc. Plug Loads | AC Energy | Home electronics socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
110 | DHO_PerScan.csv | Dhofar | 62 | SPARE_kWhN03C_kWh | kWh | Floating Point | Miscellaneous | AC Energy | Unused meter channel | 20 seconds | None | 2014-11-18 12:00:20 | |||
111 | DHO_PerScan.csv | Dhofar | 63 | Lighting_Fans_A_kWh | kWh | Floating Point | Lighting; Water/HVAC | AC Energy | Red (A) phase lighting/fan branch circuits | 20 seconds | None | 2014-11-18 12:00:20 | |||
112 | DHO_PerScan.csv | Dhofar | 64 | Lighting_Fans_B_kWh | kWh | Floating Point | Lighting; Water/HVAC | AC Energy | Yellow (B) phase lighting/fan branch circuits | 20 seconds | None | 2014-11-18 12:00:20 | |||
113 | DHO_PerScan.csv | Dhofar | 65 | Lighting_Fans_C_kWh | kWh | Floating Point | Lighting; Water/HVAC | AC Energy | Blue (C) phase lighting/fan branch circuits | 20 seconds | None | 2014-11-18 12:00:20 | |||
114 | DHO_PerScan.csv | Dhofar | 66 | Production_kWh | kWh | Floating Point | Power Generation | AC Energy | PV inverter feeder | 20 seconds | None | 2014-11-18 12:00:20 | |||
115 | DHO_PerScan.csv | Dhofar | 67 | SPARE_kWhN05B_kWh | kWh | Floating Point | Miscellaneous | AC Energy | Unused meter channel | 20 seconds | None | 2014-11-18 12:00:20 | |||
116 | DHO_PerScan.csv | Dhofar | 68 | SPARE_kWhN05C_kWh | kWh | Floating Point | Miscellaneous | AC Energy | Unused meter channel | 20 seconds | None | 2014-11-18 12:00:20 | |||
117 | DHO_PerScan.csv | Dhofar | 69 | Consumption_kWh | kWh | Floating Point | Electrical Service | AC Energy | Combined service | 20 seconds | None | 2014-11-18 12:00:20 | |||
118 | DHO_PerScan.csv | Dhofar | 70 | Lighting_Fans_kWh | kWh | Floating Point | Lighting; Water/HVAC | AC Energy | Combined lighting/fan branch circuits | 20 seconds | None | 2014-11-18 12:00:20 | |||
119 | DHO_PerScan.csv | Dhofar | 71 | Grid_kWh | kWh | Floating Point | Electrical Service | AC Energy | Net service/PV inverter feeder | 20 seconds | None | 2014-11-18 12:00:20 | |||
120 | GUT_PerScan.csv | GUtech | 1 | TmStamp | Timestamp | Timestamp | Timestamp | 20 seconds | None | 2014-11-18 12:00:20 | |||||
121 | GUT_PerScan.csv | GUtech | 2 | PowerSupply_V | V | Floating Point | Miscellaneous | DC Voltage | Datalogger power supply | 20 seconds | None | 2014-11-18 12:00:20 | |||
122 | GUT_PerScan.csv | GUtech | 3 | Datalogger_degC | °C | Floating Point | Miscellaneous | Dry-Bulb Temperature | Datalogger wiring panel | 20 seconds | None | 2014-11-18 12:00:20 | |||
123 | GUT_PerScan.csv | GUtech | 4 | Zone1_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 1 (Dining Space) | 20 seconds | None | 2014-11-18 12:00:20 | |||
124 | GUT_PerScan.csv | GUtech | 5 | Zone1_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 1 (Dining Space) | 20 seconds | None | 2014-11-18 12:00:20 | |||
125 | GUT_PerScan.csv | GUtech | 6 | Zone2_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 2 (Living Space) | 20 seconds | None | 2014-11-18 12:00:20 | |||
126 | GUT_PerScan.csv | GUtech | 7 | Zone2_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 2 (Living Space) | 20 seconds | None | 2014-11-18 12:00:20 | |||
127 | GUT_PerScan.csv | GUtech | 8 | Zone3_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 3 (Middle Bedroom) | 20 seconds | None | 2014-11-18 12:00:20 | |||
128 | GUT_PerScan.csv | GUtech | 9 | Zone3_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 3 (Middle Bedroom) | 20 seconds | None | 2014-11-18 12:00:20 | |||
129 | GUT_PerScan.csv | GUtech | 10 | Zone4_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 4 (East/West Bedroom) | 20 seconds | None | 2014-11-18 12:00:20 | |||
130 | GUT_PerScan.csv | GUtech | 11 | Zone4_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 4 (East/West Bedroom) | 20 seconds | None | 2014-11-18 12:00:20 | |||
131 | GUT_PerScan.csv | GUtech | 12 | Zone1Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 1 (Dining Space) radiation shield fan | 20 seconds | None | 2014-11-18 12:00:20 | |||
132 | GUT_PerScan.csv | GUtech | 13 | Zone2Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 2 (Living Space) radiation shield fan | 20 seconds | None | 2014-11-18 12:00:20 | |||
133 | GUT_PerScan.csv | GUtech | 14 | Zone3Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 3 (Middle Bedroom) radiation shield fan | 20 seconds | None | 2014-11-18 12:00:20 | |||
134 | GUT_PerScan.csv | GUtech | 15 | Zone4Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 4 (East/West Bedroom) radiation shield fan | 20 seconds | None | 2014-11-18 12:00:20 | |||
135 | GUT_PerScan.csv | GUtech | 16 | Shower_degC | °C | Floating Point | Water/HVAC | Dry-Bulb Temperature | Shower outlet | 20 seconds | None | 2014-11-18 12:00:20 | |||
136 | GUT_PerScan.csv | GUtech | 17 | Shower_L | L | Floating Point | Water/HVAC | Liquid Volume | Shower outlet | 20 seconds | None | 2014-11-18 12:00:20 | |||
137 | GUT_PerScan.csv | GUtech | 18 | Dishwasher_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Dishwasher | 20 seconds | None | 2014-11-18 12:00:20 | |||
138 | GUT_PerScan.csv | GUtech | 19 | Fridge_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Refrigerator | 20 seconds | None | 2014-11-18 12:00:20 | |||
139 | GUT_PerScan.csv | GUtech | 20 | Freezer_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Freezer | 20 seconds | None | 2014-11-18 12:00:20 | |||
140 | GUT_PerScan.csv | GUtech | 21 | PotTemp_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Cooking task pot | 20 seconds | None | 2014-11-18 12:00:20 | |||
141 | GUT_PerScan.csv | GUtech | 22 | PotLevel_inch | in. | Floating Point | Appliances | Liquid Level | Cooking task pot | 20 seconds | None | 2014-11-18 12:00:20 | |||
142 | GUT_PerScan.csv | GUtech | 23 | Grid_A_W | W | Floating Point | Electrical Service | AC Power | Red (A) phase service | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
143 | GUT_PerScan.csv | GUtech | 24 | Grid_B_W | W | Floating Point | Electrical Service | AC Power | Yellow (B) phase service | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
144 | GUT_PerScan.csv | GUtech | 25 | Grid_C_W | W | Floating Point | Electrical Service | AC Power | Blue (C) phase service | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
145 | GUT_PerScan.csv | GUtech | 26 | Inverter_ A_W | W | Floating Point | Power Generation | AC Power | Red (A) PV inverter feeder | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
146 | GUT_PerScan.csv | GUtech | 27 | Inverter_ B_W | W | Floating Point | Power Generation | AC Power | Yellow (B) PV inverter feeder | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
147 | GUT_PerScan.csv | GUtech | 28 | Inverter_C_W | W | Floating Point | Power Generation | AC Power | Blue (C) PV inverter feeder | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
148 | GUT_PerScan.csv | GUtech | 29 | Chiller_A_Pumps_W | W | Floating Point | Water/HVAC | AC Power | Red (A) phase chiller and pumps branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
149 | GUT_PerScan.csv | GUtech | 30 | Chiller_B_AHU_W | W | Floating Point | Water/HVAC | AC Power | Yellow (B) phase chiller and AHU branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
150 | GUT_PerScan.csv | GUtech | 31 | Chiller_C_W | W | Floating Point | Water/HVAC | AC Power | Blue (C) phase chiller branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
151 | GUT_PerScan.csv | GUtech | 32 | LIV_DIN_Lights_W | W | Floating Point | Lighting | AC Power | Living and dining rooms branch circuits | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
152 | GUT_PerScan.csv | GUtech | 33 | RangeHood_W | W | Floating Point | Appliances; Lighting | AC Power | Range hood (with integrated light) branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
153 | GUT_PerScan.csv | GUtech | 34 | FridgeFreezer_W | W | Floating Point | Appliances | AC Power | Refrigerator/freezer socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
154 | GUT_PerScan.csv | GUtech | 35 | Cooktop_W | W | Floating Point | Appliances | AC Power | Cooktop socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
155 | GUT_PerScan.csv | GUtech | 36 | ClothesWasher_W | W | Floating Point | Appliances | AC Power | Clothes washer socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
156 | GUT_PerScan.csv | GUtech | 37 | Non_LIV_DIN_Lights_W | W | Floating Point | Lighting; Water/HVAC | AC Power | Lighting (except living and dining rooms) branch circuits | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
157 | GUT_PerScan.csv | GUtech | 38 | Dishwasher_W | W | Floating Point | Appliances | AC Power | Dishwasher socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
158 | GUT_PerScan.csv | GUtech | 39 | HomeElectronics_W | W | Floating Point | Misc. Plug Loads | AC Power | Home electronics socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
159 | GUT_PerScan.csv | GUtech | 40 | DAS_A_W | W | Floating Point | Miscellaneous | AC Power | Red (A) phase data acquisition system branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
160 | GUT_PerScan.csv | GUtech | 41 | Grid_W | W | Floating Point | Electrical Service | AC Power | Combined service | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
161 | GUT_PerScan.csv | GUtech | 42 | Inverter_W | W | Floating Point | Power Generation | AC Power | Combined PV inverter feeder | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
162 | GUT_PerScan.csv | GUtech | 43 | Chiller_AHU_Pumps_W | W | Floating Point | Water/HVAC | AC Power | Combined chiller/AHU/pumps branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
163 | GUT_PerScan.csv | GUtech | 44 | Grid_A_kWh | kWh | Floating Point | Electrical Service | AC Energy | Red (A) phase service | 20 seconds | None | 2014-11-18 12:00:20 | |||
164 | GUT_PerScan.csv | GUtech | 45 | Grid_B_kWh | kWh | Floating Point | Electrical Service | AC Energy | Yellow (B) phase service | 20 seconds | None | 2014-11-18 12:00:20 | |||
165 | GUT_PerScan.csv | GUtech | 46 | Grid_C_kWh | kWh | Floating Point | Electrical Service | AC Energy | Blue (C) phase service | 20 seconds | None | 2014-11-18 12:00:20 | |||
166 | GUT_PerScan.csv | GUtech | 47 | Inverter_ A_kWh | kWh | Floating Point | Power Generation | AC Energy | Red (A) PV inverter feeder | 20 seconds | None | 2014-11-18 12:00:20 | |||
167 | GUT_PerScan.csv | GUtech | 48 | Inverter_ B_kWh | kWh | Floating Point | Power Generation | AC Energy | Yellow (B) PV inverter feeder | 20 seconds | None | 2014-11-18 12:00:20 | |||
168 | GUT_PerScan.csv | GUtech | 49 | Inverter_C_kWh | kWh | Floating Point | Power Generation | AC Energy | Blue (C) PV inverter feeder | 20 seconds | None | 2014-11-18 12:00:20 | |||
169 | GUT_PerScan.csv | GUtech | 50 | Chiller_A_Pumps_kWh | kWh | Floating Point | Water/HVAC | AC Energy | Red (A) phase chiller and pumps branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
170 | GUT_PerScan.csv | GUtech | 51 | Chiller_B_AHU_kWh | kWh | Floating Point | Water/HVAC | AC Energy | Yellow (B) phase chiller and AHU branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
171 | GUT_PerScan.csv | GUtech | 52 | Chiller_C_kWh | kWh | Floating Point | Water/HVAC | AC Energy | Blue (C) phase chiller branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
172 | GUT_PerScan.csv | GUtech | 53 | LIV_DIN_Lights_kWh | kWh | Floating Point | Lighting | AC Energy | Living and dining rooms branch circuits | 20 seconds | None | 2014-11-18 12:00:20 | |||
173 | GUT_PerScan.csv | GUtech | 54 | RangeHood_kWh | kWh | Floating Point | Appliances; Lighting | AC Energy | Range hood (with integrated light) branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
174 | GUT_PerScan.csv | GUtech | 55 | FridgeFreezer_kWh | kWh | Floating Point | Appliances | AC Energy | Refrigerator/freezer socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
175 | GUT_PerScan.csv | GUtech | 56 | Cooktop_kWh | kWh | Floating Point | Appliances | AC Energy | Cooktop socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
176 | GUT_PerScan.csv | GUtech | 57 | ClothesWasher_kWh | kWh | Floating Point | Appliances | AC Energy | Clothes washer socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
177 | GUT_PerScan.csv | GUtech | 58 | Non_LIV_DIN_Lights_kWh | kWh | Floating Point | Lighting; Water/HVAC | AC Energy | Lighting (except living and dining rooms) branch circuits | 20 seconds | None | 2014-11-18 12:00:20 | |||
178 | GUT_PerScan.csv | GUtech | 59 | Dishwasher_kWh | kWh | Floating Point | Appliances | AC Energy | Dishwasher socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
179 | GUT_PerScan.csv | GUtech | 60 | HomeElectronics_kWh | kWh | Floating Point | Misc. Plug Loads | AC Energy | Home electronics socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
180 | GUT_PerScan.csv | GUtech | 61 | DAS_A_kWh | kWh | Floating Point | Miscellaneous | AC Energy | Red (A) phase data acquisition system branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
181 | GUT_PerScan.csv | GUtech | 62 | Grid_kWh | kWh | Floating Point | Electrical Service | AC Energy | Combined service | 20 seconds | None | 2014-11-18 12:00:20 | |||
182 | GUT_PerScan.csv | GUtech | 63 | Inverter_kWh | kWh | Floating Point | Power Generation | AC Energy | Combined PV inverter feeder | 20 seconds | None | 2014-11-18 12:00:20 | |||
183 | GUT_PerScan.csv | GUtech | 64 | Chiller_AHU_Pumps_kWh | kWh | Floating Point | Water/HVAC | AC Energy | Combined chiller/AHU/pumps branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
184 | HCT_PerScan.csv | HCT | 1 | TmStamp | Timestamp | Timestamp | Timestamp | 20 seconds | None | 2014-11-18 12:00:20 | |||||
185 | HCT_PerScan.csv | HCT | 2 | PowerSupply_V | V | Floating Point | Miscellaneous | DC Voltage | Datalogger power supply | 20 seconds | None | 2014-11-18 12:00:20 | |||
186 | HCT_PerScan.csv | HCT | 3 | Datalogger_degC | °C | Floating Point | Miscellaneous | Dry-Bulb Temperature | Datalogger wiring panel | 20 seconds | None | 2014-11-18 12:00:20 | |||
187 | HCT_PerScan.csv | HCT | 4 | GlobalHoriz_Wm2 | W/m² | Floating Point | Outdoor Environment | Solar Radiation | Weather station | 20 seconds | None | 2014-11-18 12:00:20 | |||
188 | HCT_PerScan.csv | HCT | 5 | WindSpeed_mps | m/s | Floating Point | Outdoor Environment | Air Speed | Weather station wind | 20 seconds | None | 2014-11-18 12:00:20 | |||
189 | HCT_PerScan.csv | HCT | 6 | OutsideAir_degC | °C | Floating Point | Outdoor Environment | Dry-Bulb Temperature | Weather station | 20 seconds | None | 2014-11-18 12:00:20 | |||
190 | HCT_PerScan.csv | HCT | 7 | OutsideAir_pctRH | %RH | Floating Point | Outdoor Environment | Relative Humdity | Weather station | 20 seconds | None | 2014-11-18 12:00:20 | |||
191 | HCT_PerScan.csv | HCT | 8 | OutsideAirShield_degC | °C | Floating Point | Radiation Shields | Dry-Bulb Temperature | Weather station radiation shield | 20 seconds | None | 2014-11-18 12:00:20 | |||
192 | HCT_PerScan.csv | HCT | 9 | Zone1_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 1 (Living Room) | 20 seconds | None | 2014-11-18 12:00:20 | |||
193 | HCT_PerScan.csv | HCT | 10 | Zone1_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 1 (Living Room) | 20 seconds | None | 2014-11-18 12:00:20 | |||
194 | HCT_PerScan.csv | HCT | 11 | Zone2_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 2 (Master Bedroom) | 20 seconds | None | 2014-11-18 12:00:20 | |||
195 | HCT_PerScan.csv | HCT | 12 | Zone2_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 2 (Master Bedroom) | 20 seconds | None | 2014-11-18 12:00:20 | |||
196 | HCT_PerScan.csv | HCT | 13 | Zone3_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 3 (West Bedrooms) | 20 seconds | None | 2014-11-18 12:00:20 | |||
197 | HCT_PerScan.csv | HCT | 14 | Zone3_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 3 (West Bedrooms) | 20 seconds | None | 2014-11-18 12:00:20 | |||
198 | HCT_PerScan.csv | HCT | 15 | Zone4_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 4 (Majlis) | 20 seconds | None | 2014-11-18 12:00:20 | |||
199 | HCT_PerScan.csv | HCT | 16 | Zone4_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 4 (Majlis) | 20 seconds | None | 2014-11-18 12:00:20 | |||
200 | HCT_PerScan.csv | HCT | 17 | DutyCycle_pct | % | Floating Point | Radiation Shields | Duty Cycle | Weather station radiation shield fan input | 20 seconds | None | 2014-11-18 12:00:20 | |||
201 | HCT_PerScan.csv | HCT | 18 | Zone1Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 1 (Living Room) | 20 seconds | None | 2014-11-18 12:00:20 | |||
202 | HCT_PerScan.csv | HCT | 19 | Zone2Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 2 (Master Bedroom) | 20 seconds | None | 2014-11-18 12:00:20 | |||
203 | HCT_PerScan.csv | HCT | 20 | Zone3Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 3 (West Bedrooms) | 20 seconds | None | 2014-11-18 12:00:20 | |||
204 | HCT_PerScan.csv | HCT | 21 | Zone4Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 4 (Majlis) | 20 seconds | None | 2014-11-18 12:00:20 | |||
205 | HCT_PerScan.csv | HCT | 22 | OutsideFan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Weather station radiation shield fan | 20 seconds | None | 2014-11-18 12:00:20 | |||
206 | HCT_PerScan.csv | HCT | 23 | Shower_degC | °C | Floating Point | Water/HVAC | Dry-Bulb Temperature | Shower outlet | 20 seconds | None | 2014-11-18 12:00:20 | |||
207 | HCT_PerScan.csv | HCT | 24 | Shower_L | L | Floating Point | Water/HVAC | Liquid Volume | Shower outlet | 20 seconds | None | 2014-11-18 12:00:20 | |||
208 | HCT_PerScan.csv | HCT | 25 | Dishwasher_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Dishwasher | 20 seconds | None | 2014-11-18 12:00:20 | |||
209 | HCT_PerScan.csv | HCT | 26 | Fridge_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Refrigerator | 20 seconds | None | 2014-11-18 12:00:20 | |||
210 | HCT_PerScan.csv | HCT | 27 | Freezer_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Freezer | 20 seconds | None | 2014-11-18 12:00:20 | |||
211 | HCT_PerScan.csv | HCT | 28 | PotTemp_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Cooking task pot | 20 seconds | None | 2014-11-18 12:00:20 | |||
212 | HCT_PerScan.csv | HCT | 29 | PotLevel_inch | in. | Floating Point | Appliances | Liquid Level | Cooking task pot | 20 seconds | None | 2014-11-18 12:00:20 | |||
213 | HCT_PerScan.csv | HCT | 30 | Grid_W | W | Floating Point | Electrical Service | AC Power | Service | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
214 | HCT_PerScan.csv | HCT | 31 | Inverters_W | W | Floating Point | Power Generation | AC Power | PV inverter feeders | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
215 | HCT_PerScan.csv | HCT | 32 | Lighting_W | W | Floating Point | Lighting; Water/HVAC | AC Power | Lighting/exhaust fans feeders | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
216 | HCT_PerScan.csv | HCT | 33 | FF_OutdoorAC_W | W | Floating Point | Water/HVAC | AC Power | First floor outdoor AC unit branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
217 | HCT_PerScan.csv | HCT | 34 | GF_OutdoorAC_W | W | Floating Point | Water/HVAC | AC Power | Ground floor outdoor AC unit branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
218 | HCT_PerScan.csv | HCT | 35 | FF_IndoorAC_W | W | Floating Point | Water/HVAC | AC Power | First floor indoor AC unit branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
219 | HCT_PerScan.csv | HCT | 36 | WaterHeater_W | W | Floating Point | Water/HVAC | AC Power | Solar water heater heating element branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
220 | HCT_PerScan.csv | HCT | 37 | Dishwasher_W | W | Floating Point | Appliances | AC Power | Dishwasher socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
221 | HCT_PerScan.csv | HCT | 38 | GF_IndoorAC_W | W | Floating Point | Water/HVAC | AC Power | Ground floor indoor AC unit branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
222 | HCT_PerScan.csv | HCT | 39 | Cooktop_W | W | Floating Point | Appliances | AC Power | Cooktop branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
223 | HCT_PerScan.csv | HCT | 40 | CablePhoneFire_W | W | Floating Point | Miscellaneous; Lighting | AC Power | Cable/network/fire equipment circuit; plug lights during competition | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
224 | HCT_PerScan.csv | HCT | 41 | ClothesWasher_W | W | Floating Point | Appliances | AC Power | Clothes washer socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
225 | HCT_PerScan.csv | HCT | 42 | FridgeFreezer_W | W | Floating Point | Appliances | AC Power | Refrigerator/freezer socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
226 | HCT_PerScan.csv | HCT | 43 | HomeElectronics_W | W | Floating Point | Misc. Plug Loads | AC Power | Home electronics socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
227 | HCT_PerScan.csv | HCT | 44 | DAS_W | W | Floating Point | Miscellaneous | AC Power | Data acquisition system branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
228 | HCT_PerScan.csv | HCT | 45 | Grid_kWh | kWh | Floating Point | Electrical Service | AC Energy | Service | 20 seconds | None | 2014-11-18 12:00:20 | |||
229 | HCT_PerScan.csv | HCT | 46 | Inverters_kWh | kWh | Floating Point | Power Generation | AC Energy | PV inverter feeders | 20 seconds | None | 2014-11-18 12:00:20 | |||
230 | HCT_PerScan.csv | HCT | 47 | Lighting_kWh | kWh | Floating Point | Lighting; Water/HVAC | AC Energy | Lighting/exhaust fans feeders | 20 seconds | None | 2014-11-18 12:00:20 | |||
231 | HCT_PerScan.csv | HCT | 48 | FF_OutdoorAC_kWh | kWh | Floating Point | Water/HVAC | AC Energy | First floor outdoor AC unit branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
232 | HCT_PerScan.csv | HCT | 49 | GF_OutdoorAC_kWh | kWh | Floating Point | Water/HVAC | AC Energy | Ground floor outdoor AC unit branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
233 | HCT_PerScan.csv | HCT | 50 | FF_IndoorAC_kWh | kWh | Floating Point | Water/HVAC | AC Energy | First floor indoor AC unit branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
234 | HCT_PerScan.csv | HCT | 51 | WaterHeater_kWh | kWh | Floating Point | Water/HVAC | AC Energy | Solar water heater heating element branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
235 | HCT_PerScan.csv | HCT | 52 | Dishwasher_kWh | kWh | Floating Point | Appliances | AC Energy | Dishwasher socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
236 | HCT_PerScan.csv | HCT | 53 | GF_IndoorAC_kWh | kWh | Floating Point | Water/HVAC | AC Energy | Ground floor indoor AC unit branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
237 | HCT_PerScan.csv | HCT | 54 | Cooktop_kWh | kWh | Floating Point | Appliances | AC Energy | Cooktop branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
238 | HCT_PerScan.csv | HCT | 55 | CablePhoneFire_kWh | kWh | Floating Point | Miscellaneous; Lighting | AC Energy | Cable/network/fire equipment circuit; plug lights during competition | 20 seconds | None | 2014-11-18 12:00:20 | |||
239 | HCT_PerScan.csv | HCT | 56 | ClothesWasher_kWh | kWh | Floating Point | Appliances | AC Energy | Clothes washer socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
240 | HCT_PerScan.csv | HCT | 57 | FridgeFreezer_kWh | kWh | Floating Point | Appliances | AC Energy | Refrigerator/freezer socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
241 | HCT_PerScan.csv | HCT | 58 | HomeElectronics_kWh | kWh | Floating Point | Misc. Plug Loads | AC Energy | Home electronics socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
242 | HCT_PerScan.csv | HCT | 59 | DAS_kWh | kWh | Floating Point | Miscellaneous | AC Energy | Data acquisition system branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
243 | NIZ_PerScan.csv | NIZ | 1 | TmStamp | Timestamp | Timestamp | Timestamp | 20 seconds | None | 2014-11-18 12:00:20 | |||||
244 | NIZ_PerScan.csv | NIZ | 2 | PowerSupply_V | V | Floating Point | Miscellaneous | DC Voltage | Datalogger power supply | 20 seconds | None | 2014-11-18 12:00:20 | |||
245 | NIZ_PerScan.csv | NIZ | 3 | Datalogger_degC | °C | Floating Point | Miscellaneous | Dry-Bulb Temperature | Datalogger wiring panel | 20 seconds | None | 2014-11-18 12:00:20 | |||
246 | NIZ_PerScan.csv | NIZ | 4 | GlobalHoriz_Wm2 | W/m² | Floating Point | Outdoor Environment | Solar Radiation | Weather station | 20 seconds | None | 2014-11-18 12:00:20 | |||
247 | NIZ_PerScan.csv | NIZ | 5 | WindSpeed_mps | m/s | Floating Point | Outdoor Environment | Air Speed | Weather station wind | 20 seconds | None | 2014-11-18 12:00:20 | |||
248 | NIZ_PerScan.csv | NIZ | 6 | OutsideAir_degC | °C | Floating Point | Outdoor Environment | Dry-Bulb Temperature | Weather station | 20 seconds | None | 2014-11-18 12:00:20 | |||
249 | NIZ_PerScan.csv | NIZ | 7 | OutsideAir_pctRH | %RH | Floating Point | Outdoor Environment | Relative Humdity | Weather station | 20 seconds | None | 2014-11-18 12:00:20 | |||
250 | NIZ_PerScan.csv | NIZ | 8 | OutsideAirShield_degC | °C | Floating Point | Radiation Shields | Dry-Bulb Temperature | Weather station radiation shield | 20 seconds | None | 2014-11-18 12:00:20 | |||
251 | NIZ_PerScan.csv | NIZ | 9 | Zone1_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 1 (Majlis) | 20 seconds | None | 2014-11-18 12:00:20 | |||
252 | NIZ_PerScan.csv | NIZ | 10 | Zone1_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 1 (Majlis) | 20 seconds | None | 2014-11-18 12:00:20 | |||
253 | NIZ_PerScan.csv | NIZ | 11 | Zone2_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 2 (Dining/Ground Floor Sitting Rooms) | 20 seconds | None | 2014-11-18 12:00:20 | |||
254 | NIZ_PerScan.csv | NIZ | 12 | Zone2_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 2 (Dining/Ground Floor Sitting Rooms) | 20 seconds | None | 2014-11-18 12:00:20 | |||
255 | NIZ_PerScan.csv | NIZ | 13 | Zone3_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 3 (Kids' Bedrooms) | 20 seconds | None | 2014-11-18 12:00:20 | |||
256 | NIZ_PerScan.csv | NIZ | 14 | Zone3_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 3 (Kids' Bedrooms) | 20 seconds | None | 2014-11-18 12:00:20 | |||
257 | NIZ_PerScan.csv | NIZ | 15 | Zone4_degC | °C | Floating Point | Indoor Environment | Dry-Bulb Temperature | Zone 4 (Master Bedroom) | 20 seconds | None | 2014-11-18 12:00:20 | |||
258 | NIZ_PerScan.csv | NIZ | 16 | Zone4_pctRH | %RH | Floating Point | Indoor Environment | Relative Humdity | Zone 4 (Master Bedroom) | 20 seconds | None | 2014-11-18 12:00:20 | |||
259 | NIZ_PerScan.csv | NIZ | 17 | DutyCycle_pct | % | Floating Point | Radiation Shields | Duty Cycle | Weather station radiation shield fan input | 20 seconds | None | 2014-11-18 12:00:20 | |||
260 | NIZ_PerScan.csv | NIZ | 18 | Zone1Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 1 (Majlis) | 20 seconds | None | 2014-11-18 12:00:20 | |||
261 | NIZ_PerScan.csv | NIZ | 19 | Zone2Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 2 (Dining/Ground Floor Sitting Rooms) | 20 seconds | None | 2014-11-18 12:00:20 | |||
262 | NIZ_PerScan.csv | NIZ | 20 | Zone3Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 3 (Kids' Bedrooms) | 20 seconds | None | 2014-11-18 12:00:20 | |||
263 | NIZ_PerScan.csv | NIZ | 21 | Zone4Fan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Zone 4 (Master Bedroom) | 20 seconds | None | 2014-11-18 12:00:20 | |||
264 | NIZ_PerScan.csv | NIZ | 22 | OutsideFan_rpm | rpm | Floating Point | Radiation Shields | Frequency of Rotation | Weather station radiation shield fan | 20 seconds | None | 2014-11-18 12:00:20 | |||
265 | NIZ_PerScan.csv | NIZ | 23 | Shower_degC | °C | Floating Point | Water/HVAC | Dry-Bulb Temperature | Shower outlet | 20 seconds | None | 2014-11-18 12:00:20 | |||
266 | NIZ_PerScan.csv | NIZ | 24 | Shower_L | L | Floating Point | Water/HVAC | Liquid Volume | Shower outlet | 20 seconds | None | 2014-11-18 12:00:20 | |||
267 | NIZ_PerScan.csv | NIZ | 25 | Dishwasher_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Dishwasher | 20 seconds | None | 2014-11-18 12:00:20 | |||
268 | NIZ_PerScan.csv | NIZ | 26 | Fridge_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Refrigerator | 20 seconds | None | 2014-11-18 12:00:20 | |||
269 | NIZ_PerScan.csv | NIZ | 27 | Freezer_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Freezer | 20 seconds | None | 2014-11-18 12:00:20 | |||
270 | NIZ_PerScan.csv | NIZ | 28 | PotTemp_degC | °C | Floating Point | Appliances | Dry-Bulb Temperature | Cooking task pot | 20 seconds | None | 2014-11-18 12:00:20 | |||
271 | NIZ_PerScan.csv | NIZ | 29 | PotLevel_inch | in. | Floating Point | Appliances | Liquid Level | Cooking task pot | 20 seconds | None | 2014-11-18 12:00:20 | |||
272 | NIZ_PerScan.csv | NIZ | 30 | Grid_A_W | W | Floating Point | Electrical Service | AC Power | Red (A) phase service | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
273 | NIZ_PerScan.csv | NIZ | 31 | Grid_B_W | W | Floating Point | Electrical Service | AC Power | Yellow (B) phase service | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
274 | NIZ_PerScan.csv | NIZ | 32 | Grid_C_W | W | Floating Point | Electrical Service | AC Power | Blue (C) phase service | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
275 | NIZ_PerScan.csv | NIZ | 33 | Inverter_A_W | W | Floating Point | Power Generation | AC Power | Red (A) phase PV inverter feeder | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
276 | NIZ_PerScan.csv | NIZ | 34 | Inverter_B_W | W | Floating Point | Power Generation | AC Power | Yellow (B) phase PV inverter feeder | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
277 | NIZ_PerScan.csv | NIZ | 35 | Inverter_C_W | W | Floating Point | Power Generation | AC Power | Blue (C) phase PV inverter feeder | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
278 | NIZ_PerScan.csv | NIZ | 36 | ClothesWasher_W | W | Floating Point | Appliances | AC Power | Clothes washer socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
279 | NIZ_PerScan.csv | NIZ | 37 | Dishwasher_W | W | Floating Point | Appliances | AC Power | Dishwasher socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
280 | NIZ_PerScan.csv | NIZ | 38 | HomeElectronics_W | W | Floating Point | Misc. Plug Loads | AC Power | Home electronics socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
281 | NIZ_PerScan.csv | NIZ | 39 | AirConditioning_A_W | W | Floating Point | Water/HVAC | AC Power | Red (A) phase air conditioning branch circuits | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
282 | NIZ_PerScan.csv | NIZ | 40 | AirConditioning_B_W | W | Floating Point | Water/HVAC | AC Power | Yellow (B) phase air conditioning branch circuits | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
283 | NIZ_PerScan.csv | NIZ | 41 | AirConditioning_C_W | W | Floating Point | Water/HVAC | AC Power | Blue (C) phase air conditioning branch circuits | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
284 | NIZ_PerScan.csv | NIZ | 42 | Lighting_GF_W | W | Floating Point | Lighting; Water/HVAC | AC Power | Ground floor lighting/exhaust fans feeder | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
285 | NIZ_PerScan.csv | NIZ | 43 | Lighting_FF_W | W | Floating Point | Lighting | AC Power | First floor lighting feeder | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
286 | NIZ_PerScan.csv | NIZ | 44 | DesertCoolingPump_W | W | Floating Point | Water/HVAC | AC Power | Desert cooling pump branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
287 | NIZ_PerScan.csv | NIZ | 45 | Range_W | W | Floating Point | Appliances | AC Power | Cooker/ranger branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
288 | NIZ_PerScan.csv | NIZ | 46 | FridgeFreezer_W | W | Floating Point | Appliances | AC Power | Refrigerator/freezer socket branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
289 | NIZ_PerScan.csv | NIZ | 47 | TankPumps_W | W | Floating Point | Water/HVAC | AC Power | Tank pumps sockets branch circuit | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
290 | NIZ_PerScan.csv | NIZ | 48 | Grid_W | W | Floating Point | Electrical Service | AC Power | Combined service | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
291 | NIZ_PerScan.csv | NIZ | 49 | Inverter_W | W | Floating Point | Power Generation | AC Power | Combined PV inverter feeder | 20 seconds | Average of 1-second readings | 2014-11-18 12:00:20 | |||
292 | NIZ_PerScan.csv | NIZ | 50 | Grid_A_kWh | kWh | Floating Point | Electrical Service | AC Energy | Red (A) phase service | 20 seconds | None | 2014-11-18 12:00:20 | |||
293 | NIZ_PerScan.csv | NIZ | 51 | Grid_B_kWh | kWh | Floating Point | Electrical Service | AC Energy | Yellow (B) phase service | 20 seconds | None | 2014-11-18 12:00:20 | |||
294 | NIZ_PerScan.csv | NIZ | 52 | Grid_C_kWh | kWh | Floating Point | Electrical Service | AC Energy | Blue (C) phase service | 20 seconds | None | 2014-11-18 12:00:20 | |||
295 | NIZ_PerScan.csv | NIZ | 53 | Inverter_A_kWh | kWh | Floating Point | Power Generation | AC Energy | Red (A) phase PV inverter feeder | 20 seconds | None | 2014-11-18 12:00:20 | |||
296 | NIZ_PerScan.csv | NIZ | 54 | Inverter_B_kWh | kWh | Floating Point | Power Generation | AC Energy | Yellow (B) phase PV inverter feeder | 20 seconds | None | 2014-11-18 12:00:20 | |||
297 | NIZ_PerScan.csv | NIZ | 55 | Inverter_C_kWh | kWh | Floating Point | Power Generation | AC Energy | Blue (C) phase PV inverter feeder | 20 seconds | None | 2014-11-18 12:00:20 | |||
298 | NIZ_PerScan.csv | NIZ | 56 | ClothesWasher_kWh | kWh | Floating Point | Appliances | AC Energy | Clothes washer socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
299 | NIZ_PerScan.csv | NIZ | 57 | Dishwasher_kWh | kWh | Floating Point | Appliances | AC Energy | Dishwasher socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
300 | NIZ_PerScan.csv | NIZ | 58 | HomeElectronics_kWh | kWh | Floating Point | Misc. Plug Loads | AC Energy | Home electronics socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
301 | NIZ_PerScan.csv | NIZ | 59 | AirConditioning_A_kWh | kWh | Floating Point | Water/HVAC | AC Energy | Red (A) phase air conditioning branch circuits | 20 seconds | None | 2014-11-18 12:00:20 | |||
302 | NIZ_PerScan.csv | NIZ | 60 | AirConditioning_B_kWh | kWh | Floating Point | Water/HVAC | AC Energy | Yellow (B) phase air conditioning branch circuits | 20 seconds | None | 2014-11-18 12:00:20 | |||
303 | NIZ_PerScan.csv | NIZ | 61 | AirConditioning_C_kWh | kWh | Floating Point | Water/HVAC | AC Energy | Blue (C) phase air conditioning branch circuits | 20 seconds | None | 2014-11-18 12:00:20 | |||
304 | NIZ_PerScan.csv | NIZ | 62 | Lighting_GF_kWh | kWh | Floating Point | Lighting; Water/HVAC | AC Energy | Ground floor lighting/exhaust fans feeder | 20 seconds | None | 2014-11-18 12:00:20 | |||
305 | NIZ_PerScan.csv | NIZ | 63 | Lighting_FF_kWh | kWh | Floating Point | Lighting | AC Energy | First floor lighting feeder | 20 seconds | None | 2014-11-18 12:00:20 | |||
306 | NIZ_PerScan.csv | NIZ | 64 | DesertCoolingPump_kWh | kWh | Floating Point | Water/HVAC | AC Energy | Desert cooling pump branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
307 | NIZ_PerScan.csv | NIZ | 65 | Range_kWh | kWh | Floating Point | Appliances | AC Energy | Cooker/ranger branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
308 | NIZ_PerScan.csv | NIZ | 66 | FridgeFreezer_kWh | kWh | Floating Point | Appliances | AC Energy | Refrigerator/freezer socket branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
309 | NIZ_PerScan.csv | NIZ | 67 | TankPumps_kWh | kWh | Floating Point | Water/HVAC | AC Energy | Tank pumps sockets branch circuit | 20 seconds | None | 2014-11-18 12:00:20 | |||
310 | NIZ_PerScan.csv | NIZ | 68 | Grid_kWh | kWh | Floating Point | Electrical Service | AC Energy | Combined service | 20 seconds | None | 2014-11-18 12:00:20 | |||
311 | NIZ_PerScan.csv | NIZ | 69 | Inverter_kWh | kWh | Floating Point | Power Generation | AC Energy | Combined PV inverter feeder | 20 seconds | None | 2014-11-18 12:00:20 | |||
csv_metadata_id | File Name | Team | Column | Header Title | Units | Data Type | Category | Measure Type | Location | Resolution | Aggregation | First Timestamp | Last Timestamp | Details | Notes |
Monthly Raw Data Files
csv_files_id | Datalogger | Month | File Link |
---|---|---|---|
1 | Dhofar | 2014-11 | CSV (26 MB) |
2 | Dhofar | 2014-12 | CSV (62 MB) |
3 | Dhofar | 2015-01 | CSV (62 MB) |
4 | GUtech | 2014-11 | CSV (26 MB) |
5 | HCT | 2014-11 | CSV (25 MB) |
6 | Nizwa | 2014-11 | CSV (29 MB) |
7 | GUtech | 2014-12 | CSV (63 MB) |
8 | HCT | 2014-12 | CSV (59 MB) |
9 | Nizwa | 2014-12 | CSV (69 MB) |
10 | SQU | 2014-12 | CSV (36 MB) |
11 | GUtech | 2015-01 | CSV (64 MB) |
12 | HCT | 2015-01 | CSV (60 MB) |
13 | Nizwa | 2015-01 | CSV (67 MB) |
14 | SQU | 2015-01 | CSV (63 MB) |
15 | Dhofar | 2015-02 | CSV (56 MB) |
16 | Dhofar | 2015-03 | CSV (63 MB) |
17 | GUtech | 2015-02 | CSV (58 MB) |
18 | GUtech | 2015-03 | CSV (63 MB) |
19 | GUtech | 2015-04 | CSV (62 MB) |
20 | GUtech | 2015-05 | CSV (66 MB) |
21 | GUtech | 2015-06 | CSV (63 MB) |
22 | HCT | 2015-02 | CSV (54 MB) |
23 | HCT | 2015-03 | CSV (60 MB) |
24 | HCT | 2015-04 | CSV (58 MB) |
25 | HCT | 2015-05 | CSV (60 MB) |
26 | HCT | 2015-06 | CSV (59 MB) |
27 | Nizwa | 2015-02 | CSV (61 MB) |
28 | Nizwa | 2015-03 | CSV (67 MB) |
29 | Nizwa | 2015-04 | CSV (64 MB) |
30 | Nizwa | 2015-05 | CSV (67 MB) |
31 | Nizwa | 2015-06 | CSV (65 MB) |
32 | SQU | 2015-02 | CSV (57 MB) |
33 | SQU | 2015-03 | CSV (63 MB) |
34 | SQU | 2015-04 | CSV (62 MB) |
35 | SQU | 2015-05 | CSV (65 MB) |
36 | SQU | 2015-06 | CSV (66 MB) |
37 | GUtech | 2015-07 | CSV (65 MB) |
38 | HCT | 2015-07 | CSV (60 MB) |
39 | Nizwa | 2015-07 | CSV (68 MB) |
40 | SQU | 2015-07 | CSV (63 MB) |
41 | Dhofar | 2015-04 | CSV (63 MB) |
42 | Dhofar | 2015-05 | CSV (66 MB) |
43 | Dhofar | 2015-06 | CSV (64 MB) |
44 | Dhofar | 2015-07 | CSV (67 MB) |
45 | GUtech | 2015-08 | CSV (66 MB) |
46 | Dhofar | 2015-08 | CSV (66 MB) |
47 | HCT | 2015-08 | CSV (61 MB) |
48 | Nizwa | 2015-08 | CSV (67 MB) |
49 | SQU | 2015-08 | CSV (68 MB) |
50 | Dhofar | 2015-09 | CSV (63 MB) |
51 | GUtech | 2015-09 | CSV (64 MB) |
52 | HCT | 2015-09 | CSV (59 MB) |
53 | SQU | 2015-09 | CSV (66 MB) |
54 | Nizwa | 2015-09 | CSV (65 MB) |
55 | Dhofar | 2015-10 | CSV (65 MB) |
56 | GUtech | 2015-10 | CSV (66 MB) |
57 | HCT | 2015-10 | CSV (60 MB) |
58 | Nizwa | 2015-10 | CSV (68 MB) |
59 | SQU | 2015-10 | CSV (69 MB) |
60 | Dhofar | 2015-11 | CSV (63 MB) |
61 | HCT | 2015-11 | CSV (58 MB) |
62 | Nizwa | 2015-11 | CSV (68 MB) |
63 | SQU | 2015-11 | CSV (64 MB) |
64 | Dhofar | 2015-12 | CSV (62 MB) |
65 | GUtech | 2015-12 | CSV (65 MB) |
66 | HCT | 2015-12 | CSV (60 MB) |
67 | Nizwa | 2015-12 | CSV (69 MB) |
68 | GUtech | 2015-11 | CSV (63 MB) |
69 | SQU | 2015-12 | CSV (65 MB) |
70 | GUtech | 2016-01 | CSV (67 MB) |
71 | HCT | 2016-01 | CSV (60 MB) |
72 | Nizwa | 2016-01 | CSV (68 MB) |
73 | SQU | 2016-01 | CSV (63 MB) |
74 | Dhofar | 2016-01 | CSV (54 MB) |
75 | GUtech | 2016-02 | CSV (63 MB) |
76 | Dhofar | 2016-02 | CSV (17 MB) |
77 | HCT | 2016-02 | CSV (56 MB) |
78 | Nizwa | 2016-02 | CSV (63 MB) |
79 | SQU | 2016-02 | CSV (59 MB) |
80 | GUtech | 2016-03 | CSV (67 MB) |
81 | HCT | 2016-03 | CSV (60 MB) |
82 | Nizwa | 2016-03 | CSV (69 MB) |
83 | SQU | 2016-03 | CSV (64 MB) |
84 | GUtech | 2016-04 | CSV (64 MB) |
85 | HCT | 2016-04 | CSV (58 MB) |
86 | Nizwa | 2016-04 | CSV (66 MB) |
87 | SQU | 2016-04 | CSV (65 MB) |
88 | Dhofar | 2016-03 | CSV (58 MB) |
89 | Dhofar | 2016-04 | CSV (58 MB) |
90 | Dhofar | 2016-05 | CSV (62 MB) |
91 | GUtech | 2016-05 | CSV (67 MB) |
92 | HCT | 2016-05 | CSV (60 MB) |
93 | Nizwa | 2016-05 | CSV (69 MB) |
94 | SQU | 2016-05 | CSV (68 MB) |
95 | Dhofar | 2016-06 | CSV (62 MB) |
96 | GUtech | 2016-06 | CSV (65 MB) |
97 | HCT | 2016-06 | CSV (39 MB) |
98 | Nizwa | 2016-06 | CSV (66 MB) |
99 | SQU | 2016-06 | CSV (67 MB) |
100 | Dhofar | 2016-07 | CSV (25 MB) |
101 | GUtech | 2016-07 | CSV (67 MB) |
102 | Nizwa | 2016-07 | CSV (68 MB) |
103 | SQU | 2016-07 | CSV (69 MB) |
104 | Nizwa | 2016-08 | CSV (68 MB) |
105 | SQU | 2016-08 | CSV (45 MB) |
106 | GUtech | 2016-08 | CSV (66 MB) |
107 | GUtech | 2016-09 | CSV (64 MB) |
108 | Nizwa | 2016-09 | CSV (65 MB) |
109 | GUtech | 2016-10 | CSV (66 MB) |
110 | Nizwa | 2016-10 | CSV (67 MB) |
111 | Nizwa | 2016-11 | CSV (73 MB) |
112 | Nizwa | 2016-12 | CSV (67 MB) |
csv_files_id | Datalogger | Month | File Link |
Issue Tracker
Issue ID | Datalogger | Column Header | Category | First Affected Timestamp | Last Affected Timestamp | Notes |
---|---|---|---|---|---|---|
1 | GUtech | Zone2_degC | Disconnected Sensor | 2015-02-02 07:24:40 | 2015-02-02 07:27:20 | |
2 | GUtech | Zone2_pctRH | Disconnected Sensor | 2015-02-02 07:24:40 | 2015-02-02 07:27:20 | |
3 | GUtech | Zone2Fan_rpm | Disconnected Sensor | 2015-02-02 07:24:40 | 2015-02-02 07:27:20 | |
4 | GUtech | Dishwasher_degC | Disconnected Sensor | 2014-12-30 10:14:40 | ||
5 | GUtech | PotTemp_degC | Disconnected Sensor | 2014-12-30 10:14:40 | ||
6 | GUtech | PotLevel_inch | Disconnected Sensor | 2014-12-30 10:14:40 | ||
7 | Dhofar | Zone1Fan_rpm | System Startup | 2014-11-18 09:34:20 | 2014-11-18 09:34:40 | Issue only occurred during system startup, so it is not important. |
8 | Dhofar | Zone2Fan_rpm | System Startup | 2014-11-18 09:34:20 | 2014-11-18 09:34:40 | Issue only occurred during system startup, so it is not important. |
9 | Dhofar | Zone3Fan_rpm | System Startup | 2014-11-18 09:34:20 | 2014-11-18 09:34:40 | Issue only occurred during system startup, so it is not important. |
10 | Dhofar | Zone4Fan_rpm | System Startup | 2014-11-18 09:34:20 | 2014-11-18 09:34:40 | Issue only occurred during system startup, so it is not important. |
11 | Dhofar | OutsideFan_rpm | System Startup | 2014-11-18 09:34:20 | 2014-11-18 09:34:20 | Issue only occurred during system startup, so it is not important. |
12 | HCT | PowerSupply_V | Power Outage | 2015-01-14 09:21:20 | 2015-01-15 09:13:40 | |
13 | HCT | DutyCycle_pct | Power Outage | 2015-01-14 21:12:40 | 2015-01-15 06:56:20 | |
14 | HCT | Zone1Fan_rpm | Power Outage | 2015-01-14 21:13:00 | 2015-01-15 09:14:20 | Fan cycled on and off during the power outage |
15 | HCT | Zone2Fan_rpm | Power Outage | 2015-01-14 21:13:00 | 2015-01-15 09:14:20 | Fan cycled on and off during the power outage |
16 | HCT | Zone3Fan_rpm | Power Outage | 2015-01-14 21:13:00 | 2015-01-15 09:14:20 | Fan cycled on and off during the power outage |
17 | HCT | Zone4Fan_rpm | Power Outage | 2015-01-14 21:13:00 | 2015-01-15 09:14:20 | Fan cycled on and off during the power outage |
18 | HCT | OutsideFan_rpm | Power Outage | 2015-01-14 21:13:00 | 2015-01-15 06:57:20 | Fan cycled on and off during the power outage |
19 | HCT | FridgeFreezer_W | CT Overcurrent | 2015-01-19 11:57:00 | 2015-01-19 11:58:20 | Events periodically occur after this event |
20 | HCT | See Notes | Power Outage | 2015-01-14 09:21:20 | 2015-01-15 09:13:40 | The power readings from all WattNodes except for those in the outside electrical room froze during the power outage |
21 | HCT | See Notes | Power Outage | 2015-01-11 15:42:00 | 2015-01-11 18:21:40 | The power readings from all WattNodes except for those in the outside electrical room froze during the power outage |
22 | HCT | See Notes | Power Outage | 2015-01-11 18:36:20 | 2015-01-11 19:10:20 | The power readings from all WattNodes except for those in the outside electrical room froze during the power outage |
23 | Nizwa | See Notes | Power Outage | 2015-01-21 16:25:00 | 2015-01-22 13:45:00 | The power readings from all WattNodes except for those in the outside panelboard froze during the power outage |
24 | Nizwa | PowerSupply_V | Power Outage | 2015-01-21 16:25:00 | 2015-01-22 13:45:00 | |
25 | Nizwa | PowerSupply_V | Power Outage | 2015-01-14 09:36:00 | 2015-01-14 09:38:20 | |
26 | Nizwa | See Notes | Power Outage | 2015-01-14 09:36:00 | 2015-01-14 09:38:20 | The power readings from all WattNodes froze during the power outage |
27 | Nizwa | PowerSupply_V | Power Outage | 2014-12-31 08:25:40 | 2014-12-31 08:28:00 | |
28 | Nizwa | DutyCycle_pct | Power Outage | 2015-01-22 02:50:20 | 2015-01-22 06:58:20 | |
29 | Nizwa | Zone1Fan_rpm | Power Outage | 2015-01-22 02:50:20 | 2015-01-22 13:45:40 | Fan cycled on and off during the power outage |
30 | Nizwa | Zone2Fan_rpm | Power Outage | 2015-01-22 02:50:20 | 2015-01-22 13:45:40 | Fan cycled on and off during the power outage |
31 | Nizwa | Zone3Fan_rpm | Power Outage | 2015-01-22 02:50:20 | 2015-01-22 13:45:40 | Fan cycled on and off during the power outage |
32 | Nizwa | Zone4Fan_rpm | Power Outage | 2015-01-22 02:50:20 | 2015-01-22 13:45:40 | Fan cycled on and off during the power outage |
33 | Nizwa | OutsideFan_rpm | Power Outage | 2015-01-22 02:50:20 | 2015-01-22 06:59:20 | Fan cycled on and off during the power outage |
34 | SQU | PowerSupply_V | Power Outage | 2015-01-27 09:00:20 | 2015-01-27 09:22:40 | |
35 | SQU | See Notes | Power Outage | 2015-01-27 09:00:20 | 2015-01-27 09:22:40 | The power readings from all WattNodes froze during the power outage |
36 | SQU | PowerSupply_V | Power Outage | 2015-01-07 13:43:40 | 2015-01-07 14:24:00 | |
37 | SQU | See Notes | Power Outage | 2015-01-07 13:43:40 | 2015-01-07 14:24:00 | The power readings from all WattNodes froze during the power outage |
38 | SQU | PowerSupply_V | Power Outage | 2014-12-22 08:27:00 | 2014-12-22 09:07:00 | |
39 | SQU | See Notes | Power Outage | 2014-12-22 08:27:00 | 2014-12-22 09:07:00 | The power readings from all WattNodes froze during the power outage |
40 | SQU | Zone1Fan_rpm | System Startup | 2014-12-14 17:50:40 | 2014-12-14 17:51:00 | Issue only occurred during system startup, so it is not important. |
41 | SQU | Zone2Fan_rpm | System Startup | 2014-12-14 17:50:40 | 2014-12-14 17:51:00 | Issue only occurred during system startup, so it is not important. |
42 | SQU | Zone3Fan_rpm | System Startup | 2014-12-14 17:50:40 | 2014-12-14 17:51:00 | Issue only occurred during system startup, so it is not important. |
43 | SQU | Zone4Fan_rpm | System Startup | 2014-12-14 17:50:40 | 2014-12-14 17:51:00 | Issue only occurred during system startup, so it is not important. |
44 | SQU | Shower_degC | Disconnected Sensor | 2014-12-16 10:53:20 | 2014-12-16 10:53:40 | |
45 | SQU | ClothesWasher_W | CT Overcurrent | 2014-12-19 09:15:20 | 2014-12-19 09:16:20 | |
46 | SQU | ClothesWasher_W | CT Overcurrent | 2014-12-24 12:02:00 | 2014-12-24 12:02:20 | |
47 | SQU | ClothesWasher_W | CT Overcurrent | 2014-12-18 10:46:00 | 2014-12-18 10:47:00 | |
Issue ID | Datalogger | Column Header | Category | First Affected Timestamp | Last Affected Timestamp | Notes |